Bộ công tắc độ dẫn điện Gestra LRGS 15-1

Gestra

Bộ công tắc độ dẫn điện Gestra LRGS 15-1

Categories: GESTRA, Gestra - Total dissolved solids (TDS) controls
DANH MỤC SẢN PHẨM
  • NEW-FLOW
    • FLOW SYSTEM
    • LEVEL SYSTEM
    • PRESSURE SYSTEM
    • TEMPERATURE SYSTEM
    • VALVE SYSTEM
  • SETRA
    • Pressure Sensors
    • Humidity/Temperature Sensors
    • Room Pressure Monitors
    • Particle Counters
    • Pressure Calibrator
  • POMAC
    • Food & Beverages
    • Pharma
    • Chemical Industry
    • Starch
    • Liquid Transport
  • SPCO
  • UFI
    • SUCTION FILTERS
    • PRESSURE FILTERS
    • RETURN FILTERS
    • OFF-LINE FILTERS
    • TRANSMISSION FILTERS
    • AIR FILTERS
  • KITZ VALVE
    • Ball Valve
    • Butterfly Valve
    • Check Valve
    • Globe Valve
    • Gate Valve
    • Strainer
  • KANEKO
    • Solenoid Valve
    • Liquid Level Gauges
    • Ventilation Equipment
    • Others
  • GESTRA
    • Bottom blowdown valves
    • Continuous blowdown valves
    • Level Controls
    • Level Limiters
    • Safety temperature controls
    • Total dissolved solids (TDS) controls
  • GECA
    • Gas Regulators
    • Gas Filters
    • Solenoid Valve
    • Solenoid Valve Manual Reset
    • Safety Device
    • Accessories
  • VERSPEC VALVE
    • Ceramic Valves and Fittings
    • Mining Valves
    • PTFE PFA Valves
  • Thông tin chi tiết

Technical Data

Service pressure

PN25: 25 barg at 224 °C

Mechanical connection

Screwed 3⁄4″, ISO 228-1 Screwed 3⁄4″ NPT (optional)

Materials

Screw-in electrode body:
1.4571, X6CrNiMoTi17-12-2 or
1.4404, A 479 316 L (for NPT thread)
Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE
Terminal box: Polycarbonate

Measuring length & length of installation

200, 300, 400, 500, 600, 800, 1000 mm

Input

1 Input for resistance thermometer, e. g. TRG 5-53, measuring insert Pt 100

Measuring range

100 to 10000 μS/cm at 25 °C or 50 to 5000 ppm at 25 °C

Setpoint

Adjustable between 100 and 10000 μS/cm or 50 to 5000 ppm

MAX limit

Adjustable between 100 and 10000 μS/cm or 50 to 5000 ppm

Switching hysteresis

Controller output: –10 % of the adjusted setpoint MAX limit: –3 % of the adjusted MAX limit

Temperature coef cient Tk

(if a resistance thermometer Pt 100 is connected) 1.6 – 3.0 % per °C, adjustable in steps of 0.1

Supply voltages

230 V, +10 / –15 %, 50-60 Hz
115 V, +10 / –15 %, 50-60 Hz (optional)

Power consumption

5VA

Fuse

External slow-blow fuse 63 mA at 230 V External slow-blow fuse 125 mA at 115 V

Output

3 Volt-free relay contacts
5 A 230 V AC / 30 V DC cos φ = 1 (IEC 61810) Provide contactor with inference suppressor (RC combination).
Contact material: AgNi 0.15

Indicators and adjustors

1 Four-digit, seven-segment indicator, red, for showing the actual value (X) / setpoint (W) and status & malfunction messages

2 Amber LEDs for indicating the actual value (X) / setpoint (W)

1 Red LED for indicating the MAX limit
2 Green LEDs for indicating “Valve OPEN / CLOSED” 4 Pushbuttons for parameter settings

Cable entry / Electrical connection

Cable glands with integrated cable clamp,
3 x M 16 x 1.5
1 Four-pole screw-type terminal strip for mains connection 1 Three-pole screw-type terminal strip for connecting the continuous blowdown valve
1 Three-pole screw-type terminal strip for MAX limit
The terminal strips can be detached;
conductor size 1.5 mm2
4 Terminal lugs for connecting the resistance thermometer

Protection

IP 65 to DIN EN 60529

Protection class

2 (protective insulation)

Weight

Approx. 1.5 kg

Ambient temperature

when system is switched on: 0 ° … 70 °C, during operation: -10 … 70 °C

Transport temperature

–20 … +80 °C (< 100 hours), defrosting time of the de-ener- gized equipment before it can be put into operation: 24 hours.

Storage temperature

–20 … +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours.

Relative humidity

max. 95%, no moisture condensation

Site altitude

max. 2000 m

Related products

Cảm biến đo mức Gestra NRGT 26-2 NRGT 26-2s

Cảm biến đo mức Gestra NRGT 26-2 NRGT 26-2s

Bộ điều khiển mức nước Gestra NRR 2-60

Cảm biến đo mức Gestra NRGT 26-1 NRGT 26-1S

Cảm biến đo mức Gestra NRGT 26-1 NRGT 26-1S For Marine Applications

Bộ điều khiển mức nước Gestra KS 92-1

Điện cực đo mức nước Gestra NRG 16-61 NRG 17-61 NRG 19-61 NRG 111-61

Điện cực đo mức nước Gestra NRG 16-61 NRG 17-61 NRG 19-61 NRG 111-61

Điện cực đo mức nước Gestra NRG 16-36

Điện cực đo mức nước Gestra NRG 26-61

Điện cực đo mức nước Gestra NRG 26-60

THÔNG TIN LIÊN HỆ

CÔNG TY TNHH NHIỆT CƠ ĐIỆN NON NƯỚC
Địa chỉ: 156/1/19 Cộng Hoà, P. 12, Q. Tân Bình, TP. Hồ Chí Minh
Điện thoại: 0286 286 1519 - Hotline: 0909 77 3479
Email: info@nonnuoc.com.vn - Website: www.nonnuoc.com.vn

FOLLOW US

www.nonnuoc.com.vn
Copyright 2025 © Non Nước
  • TRANG CHỦ
  • GIỚI THIỆU
    • TẦM NHÌN & SỨ MỆNH
    • SƠ ĐỒ TỔ CHỨC
  • TIN TỨC
  • KHÁCH HÀNG
  • LIÊN HỆ

Login

Lost your password?